Imagen
df series manual industrial coupler female threads
Imagen
f series manual coupler_2ff2-b_cutaway cad model

2FBF2-B - Serie-F Cople Manual Intercambio Industrial (Rosca Hembra)

Dixon Distributor? 

Log in to view pricing, inventory, place orders & much more. If you want to create an account, please click the button to begin the registration process.

Atributos

Peso
0,24 lb
Break Quantity
0
Paquete Opcional/Cantidad por Caja
10
Material
Latón
DE Máximo
0.93" (23.5 mm)
Rosca
BSPP
Tamaño de Cuerpo
1/4"
Rango de Temperatura
-40°F to 250°F (-40°C to 121°C)
Medida de Rosca
1/4"
Longitud
2.07" (52.6 mm)
Hex
3/4"
Valor de Presión
See Product Details

Detalles

Compatibility & Interchange Data

  • Foster 3, 4, 5 and 6 Series
  • Parker 20-Series Manual Interchange
  • Hansen 1000, 400 and 500

Construction

  • Machined components are manufactured using solid bar stock.
  • Stainless steel balls, retaining rings and springs maximize corrosion resistance and extend service life.
  • Nitrile (Nitrile Rubber) seals are standard
  • Steel componentry is plated using ROHS Compliant Trivalent Chrome.
  • Steel sleeve and steel tubular valve

How It Works

  • To disconnect, begin by holding the hose on the nipple side with three of your fingers, leaving your thumb and index finger free.
  • Grab the sleeve with your thumb and index finger and begin to pull the sleeve towards the palm of your hand.
  • After pulling the sleeve, the nipple will move out of the coupler slightly. Continue to hold the hose and coupler sleeve until all air is fully exhausted.
  • After the line is fully exhausted, you are able to safely separate the nipple from the coupler.

Safety Notes

It is important to be safe when installing quick disconnect couplings into a pneumatic circuit. Never install a pneumatic coupling directly into an air tool, use a piece of hose that is at least 18" long, between the tool and the coupling, to prevent damage to the coupling. To protect the operator, safety devices, such as a safety check valve and safety cable should be installed in case there is a hose or coupling failure.

Specifications

  • Rated pressure for connected Brass Coupler & Brass Plug: 300 PSI (20 bar) Maximum Working and 8,500 PSI (586 bar) Burst
  • Rated pressure for connected Brass Coupler & Steel Plug: 500 PSI (35 bar) Maximum Working and 9,000 PSI (620 bar) Burst