Image
ADS Outalarm® with Capacitance Probe

A100C96A - ADS Outalarm® with Capacitance Probe

Dixon Distributor? 

Log in to view pricing, inventory, place orders & much more. If you want to create an account, please click the button to begin the registration process.

Attributes

Weight
4.5 lb
Break Quantity
1
Optional Package/Box Quantity
1
Temperature Range
-14°F to 250°F (-26°C to 121°C)
Length
96"
Pressure Rating
50 PSI, Consult Dixon for applications up to 300 PSI

Details

Applications

Specifically designed for the operation of liquid terminals in batch loading and protection against overfilling, unloading, tank cars, tank trucks, marine barges, suitable for open and closed dome.

Available Options

  • Standard probe lengths of 24", 36", 48" and 60", other lengths available
  • Optional opto-isolated solid state contact output

Construction

Wetted materials: 316 stainless steel, PTFE standard, other materials available

Features

  • Fully autonomous; without cables, tubes or external power
  • Robust construction resistant to weather and corrosion
  • No moving parts, tip-sensitive Phase Shift™ digital capacitance sensor for conductive and non-conductive fluid
  • No calibration or adjustment required
  • Runs up to 2500 hours on a single 9V alkaline battery
  • Adjustable insertion length via standard 1/2" NPT connector
  • High intensity flashing visual and audible outputs
  • Graduated and full laser engraved rod.
  • Fail-safe continuous battery monitor goes into alarm state on low battery
  • Activation point 1/4" into the liquid
  • Battery current consumption <0.23 ma during standby mode; <50 ma in alarm status
  • Horn intensity 101 dB at 2'
  • Light output 3 high intensity flashing LEDs of 3000 mcd each
  • Capacitance Phase Shift Probe
  • Cable gland standard 1/2 NPT
  • Minimum dielectric constant 1.8

Specifications

Intrinsically safe design per ANSI/UL913 Class I, Div I Groups A, B, C and D Hazardous Areas

Resources

    Request a Quote

    Need help selecting the correct components?