Temperature Range
-14°F to 250°F (-26°C to 121°C)
Length
48"
Pressure Rating
50 PSI, Consult Dixon for applications up to 300 PSI

Details

Applications

Specifically designed for the operation of liquid terminals in batch loading and protection against overfilling, unloading, tank cars, tank trucks, marine barges, suitable for open and closed dome.

Available Options

Standard probe lengths of 24", 36", 48" and 60", other lengths available

Construction

Wetted materials: 316 stainless steel, PTFE standard, other materials available

Features

  • Fully autonomous; without cables, tubes or external power
  • Robust construction resistant to weather and corrosion
  • No moving parts, tip-sensitive Phase Shift™ digital capacitance sensor for conductive and non-conductive fluids, conductivity sensor with integral splash guard
  • No calibration or adjustment required
  • Adjustable insertion length via standard 1/2" NPT connector
  • High intensity flashing visual and audible outputs
  • Optional opto-isolated solid state contact output
  • Graduated and full laser engraved rod.
  • A100 runs up to 2500 hours on a single 9V alkaline battery
  • Fail-safe continuous battery monitor goes into alarm state on low battery
  • Battery current consumption <0.23 ma during standby mode; <50 ma in alarm status

Specifications

  • Intrinsically safe design per ANSI/UL913 Class I, Div I Groups A, B, C and D Hazardous Areas
  • Minimum dielectric constant 1.7
  • Temperature Range: Probe Capacitance: -14°F to 250°F (-26°C to 121°C)
  • Activation point 1/4" into the liquid
  • Compatible with any liquid or dry bulk material with a dielectric constant of 1.7 or higher
  • Horn intensity 101 dB at 2'
  • Light output 3 high intensity flashing LEDs of 3000 mcd each
  • Pressure rating on standard unit: 50 PSI, consult Dixon® for applications up to 300 PSI